Displaying report 1-1 of 1.
Reports until 17:33, Friday 22 August 2014
H1 SUS (INS, ISC)
jeffrey.kissel@LIGO.ORG - posted 17:33, Friday 22 August 2014 (13573)
H1 SUS OMs -- TFs look OK for Chamber Close Up, Still Need Spectra
J. Kissel, D. Hoak

Completed a set of Phase 3a transfer functions and spectra to confirm the health of H1SUSOM1, OM2, and OM3 before we close doors on Monday. Results look good, and in fact, OM1 looks better -- more like the other SUS -- than before.

Raw .xmls
H1/OM1/SAGM1/Data/2014-08-22_1800_H1SUSOM1_M1_WhiteNoise_L_tf.xml
H1/OM1/SAGM1/Data/2014-08-22_1800_H1SUSOM1_M1_WhiteNoise_P_tf.xml
H1/OM1/SAGM1/Data/2014-08-22_1800_H1SUSOM1_M1_WhiteNoise_Y_tf.xml

H1/OM2/SAGM1/Data/2014-08-22_1800_H1SUSOM2_M1_WhiteNoise_L_tf.xml
H1/OM2/SAGM1/Data/2014-08-22_1800_H1SUSOM2_M1_WhiteNoise_P_tf.xml
H1/OM2/SAGM1/Data/2014-08-22_1800_H1SUSOM2_M1_WhiteNoise_Y_tf.xml

H1/OM3/SAGM1/Data/2014-08-22_2229_H1SUSOM3_M1_WhiteNoise_L_tf.xml
H1/OM3/SAGM1/Data/2014-08-22_2229_H1SUSOM3_M1_WhiteNoise_P_tf.xml
H1/OM3/SAGM1/Data/2014-08-22_2229_H1SUSOM3_M1_WhiteNoise_Y_tf.xml

Data processed by
/ligo/svncommon/SusSVN/sus/trunk/HTTS/Common/MatlabTools/plotOMCS_dtttfs.m

And saved to
/ligo/svncommon/SusSVN/sus/trunk/HTTS/H1/OM1/SAGM1/Results/2014-08-22_1800_H1SUSOM1_M1.mat
/ligo/svncommon/SusSVN/sus/trunk/HTTS/H1/OM2/SAGM1/Results/2014-08-22_1800_H1SUSOM2_M1.mat
/ligo/svncommon/SusSVN/sus/trunk/HTTS/H1/OM3/SAGM1/Results/2014-08-22_2229_H1SUSOM3_M1.mat

TFs compared with others using
/ligo/svncommon/SusSVN/sus/trunk/HTTS/Common/MatlabTools/plotallomcs_tfs.m

All data and scripts have been committed to the repo.
Non-image files attached to this report
Displaying report 1-1 of 1.