Displaying report 1-1 of 1.
Reports until 11:24, Thursday 07 March 2019
H1 ISC (CAL)
sheila.dwyer@LIGO.ORG - posted 11:24, Thursday 07 March 2019 - last comment - 03:04, Saturday 09 March 2019(47351)
noise budget plots without squeezing

Georgia, Craig, Danny, Sheila

Here are some updated noise budget plots, made for 9:30 UTC March 5th, when there was no squeezing injected. 

Some notes:

 

 

Images attached to this report
Comments related to this report
georgia.mansell@LIGO.ORG - 00:33, Friday 08 March 2019 (47387)

Dan, Craig, Georgia

We git-committed the noise budget templates used here, and have rerun the noise budget templates for MICH_P, DHARD_P, DSOFT_P (increased the excitation by a factor of 30 to make it visible in DARM). We still need to re-run the CSOFT_P template to make the ASC contribution to the noise budget up-to-date. We have added DC centering loop templates to the folder however the excitation level needs to be tuned.

A preliminary look at the ASC budget, with the old CSOFT_P measurement, (attached figure) shows we've won a in the <15 Hz region, and we still have some sensitivity to gain by improving DHARD.

 

Images attached to this comment
daniel.vander-hyde@LIGO.ORG - 03:04, Saturday 09 March 2019 (47413)

Dan, Danny, Alexi

To include the DC centering in the noise budget we excited the DC1 and DC2 pitch and yaw centering loops and DC3 yaw.  It took large amplitudes for us to see coherence in DARM that was mainly below 10 Hz. 

We also injected into the SRC1 yaw excitation point and didn't seem to see anything in DARM even with large amplitudes. 

Not sure if we are doing this right. Might be worth revisiting. We have templates made up for these. They live in /ligo/gitcommon/NoiseBudget/simple-noise-budget

Displaying report 1-1 of 1.