Displaying report 1-1 of 1.
Reports until 09:40, Monday 25 March 2013
X1 SUS
jeffrey.bartlett@LIGO.ORG - posted 09:40, Monday 25 March 2013 (5874)
Second TFs of I1-MC3
   After updating incorrect matrix values in MEDM, we reran the TFs on I1-MC3. The results look much better. There are several small non-modeled peeks near or below 0Hz in the L, R, and Y DoFs and some noise in T just below 0Hz in the undamped plots. These are mostly removed from the damped plots. The comparison plots show all these non-modeled peeks are in line with similar non-modeled peek present in other suspensions. Waiting for Testing Group to review data before making any changed to I1-MC3.   
Non-image files attached to this report