Displaying report 1-1 of 1.
Reports until 13:45, Friday 26 April 2024
H1 ISC (ISC)
jennifer.wright@LIGO.ORG - posted 13:45, Friday 26 April 2024 - last comment - 15:01, Friday 26 April 2024(77449)
Ran Bruco on DARM stretch while we were at 152MPc last night

Thanks to Elenna for the instructions!

The BRUCO can be found here and ran on 400s seconds starting at 1398159599.

Analysis in progress.

Comments related to this report
sheila.dwyer@LIGO.ORG - 14:31, Friday 26 April 2024 (77451)

Elenna's bruco instructions are at /ligo/home/elenna.capote/bruco_instructions.txt

(I've attached a copy here as well)

Non-image files attached to this comment
sheila.dwyer@LIGO.ORG - 15:01, Friday 26 April 2024 (77453)
  • There's coherence with CHARD Y and SRCL,
  • HAM4 L4C
  • CHARD P has a lot of coherence at 20 Hz, running A2L again may help clean this up.
  • A lot of HAM2 sensors around 40 Hz