Daniel, Sheila, Alexa
The TMS Baffle PD 1 220.6 PIT -227.1 YAW 2.24 Volts at 0dB gain. I saved this as the misalignment state.
Baffle PD 4 (channel 3) 289.9 PIT -289.0 YAW 2.47 V 0dB gain.
Aligned position:255.25 PIT -258.05 YAW saved as aligned state. This is a change of -0.6 PIT -0.45 YAW from yesterday and alog 10001
Then I moved PR3 using the single shot beam on the camera, it seems centered now. (PIT -244, YAW -253.98 according to PV info) However, there is something funny about the sliders on PR3: the text entry button says -253, while the number above the slider says -253.
Apparently Epics doesn't know how to round.
To get cavty flashes I moved the ETM to 243.0 PIT, 74 YAW, these are now saved as alinged.
Tha cavity locked and the IAL servos are running now.