Reports until 15:04, Thursday 13 February 2014
H1 SEI (CDS)
jeffrey.kissel@LIGO.ORG - posted 15:04, Thursday 13 February 2014 (10070)
Moved ISI and HPI ETMX Foton Files to Userapps Repo
While yak shaving today, I discovered that the ETMX HPI and ISI foton files in 
/opt/rtcds/lho/h1/chans/
were *not* soft links to the 
/opt/rtcds/userapps/release/hpi/h1/filterfiles/
/opt/rtcds/userapps/release/isi/h1/filterfiles/
folders. 

I fixed it.

controls@opsws6:chans 0$ ls -l H1*ETMX.txt
lrwxrwxrwx 1 controls controls 60 Feb 13 14:50 H1HPIETMX.txt -> /opt/rtcds/userapps/release/hpi/h1/filterfiles/H1HPIETMX.txt
lrwxrwxrwx 1 controls controls 60 Feb 13 14:51 H1ISIETMX.txt -> /opt/rtcds/userapps/release/isi/h1/filterfiles/H1ISIETMX.txt
lrwxrwxrwx 1 controls controls 60 Jul 15  2013 H1SUSETMX.txt -> /opt/rtcds/userapps/release/sus/h1/filterfiles/H1SUSETMX.txt
controls@opsws6:chans 0$ pwd
/opt/rtcds/lho/h1/chans
controls@opsws6:chans 0$

The filter files are now committed to the repo.