ISI States

Hugo has BS

ITMY is Isolating at Lvl3.  Stage1 blend is T250son rot dofs, T40NO.44 on X & Y, & T100NO44 on Z.  Stage2 has Lvl3 with 750 blends except on X & Y which have 250s.

Stefan has the Xarm and isn't complaining.  ITMX is Lvl3 TCrappy. ETMX is at Lvl3 on Stage1 & Lvl2 on Stage2 w/ TCrappys--normal logged state.

Comments related to this report
hugo.paris@LIGO.ORG - 18:33, Thursday 13 February 2014 (10082)

I put BS-IS and BS-HEPI back to their running state, prior to the foton file cleanup.

BS-ISI

  • ST1 Blend: T100mHz_0.44 on X and Y, T250mhz on all the other DOF.
  • ST2 Blend: 250mHz
  • ST1+ST2 ISO: Lv2

BS-HEPI

  • Level 2 control loops