Displaying report 1-1 of 1.
Reports until 17:47, Thursday 13 February 2014
H1 DAQ (CDS, ISC)
david.barker@LIGO.ORG - posted 17:47, Thursday 13 February 2014 - last comment - 18:10, Thursday 13 February 2014(10078)
DAQ restart, new ASC LSC models
17:44 DAQ restart. supporting new h1asc, h1ascimc, h1lsc models. This has fixed the IPC errors ASC was experiencing.
Comments related to this report
kiwamu.izumi@LIGO.ORG - 18:10, Thursday 13 February 2014 (10080)

Yuta, Kiwamu,

We made small changes on h1lsc, h1asc, h1ascimc:

  • We resolved the IPC  issue (alog 10061) by changing block's name in h1asc so that they match wiht the sender block names in the LSC model.
  • We added two new IPC blocks in h1asc which are sent from h1lsc:
    • LSC-ASC_POPAIR_B_LF
    • LSC-ASC_POPAIR_B_RF90_I
  • We deleted MC_F_LF IPC block and its anti-ailiasing filter from h1lsc as they had never been used. Note that they had been already removed from l1lsc.
  • We deleted MC_F_LF IPC reciever from h1ascimc

All these models were successfully compiled, built and installed. And they are running fine so far. Also they are now checked into the SVN.