HAM4-ISI - Ready for guardian testing

HAM4-ISI was getting mechanically preped by Hugh, Jim and Mitch today.

Meanwhile I installed all the IN/OUT filters, loaded the coordinate transform matrices, all the generic HAM-ISI blend filters, the generic damping loops and the Lv1 Isolation loops. All work properly, but the Isolation loops are unstable. I suppose something may be mis-wired as we went very fast.

Transfer functions are running overnight on HAM4-ISI, we will know for sure tomorrow.

Images attached to this report
Comments related to this report
hugo.paris@LIGO.ORG - 18:36, Thursday 13 February 2014 (10083)

SR2 is damped.