evan.hall@LIGO.ORG - posted 15:56, Tuesday 18 February 2014 - last comment - 17:22, Tuesday 18 February 2014(10155)
REFLAIR_A_RF45_Q_ERR RFAM

I misaligned the BS and ITMX and looked at the trended time series of REFLAIR_A_RF45_Q_ERR. Since the beam is (in theory) bouncing prompty off the PRM and onto the diode without any kind of Fabry-Perot interference, this signal should tell us something about 45 MHz RFAM.

The calibration (7.6 cts / nm) is from elog 10127.

Non-image files attached to this report
Comments related to this report
evan.hall@LIGO.ORG - 17:22, Tuesday 18 February 2014 (10161)ISC

As Kiwamu pointed out, the calibration must be multiplied by R_PRM / T_PRM^2, since the PD experiences the reflection of PRM rather than the doubly-transmitted beam. The plot is now corrected.