Reports until 17:01, Tuesday 18 February 2014
H1 SEI
sheila.dwyer@LIGO.ORG - posted 17:01, Tuesday 18 February 2014 - last comment - 08:03, Wednesday 19 February 2014(10160)
ITMX ISI

for some reason the ITMX ISI was using 750 blends, although Hugho left it on Tcrappy friday night (10114) and Hugh checked that things were OK this morning (10122.)

I moved it to Tcrappy on both stages

Comments related to this report
hugh.radkins@LIGO.ORG - 08:03, Wednesday 19 February 2014 (10169)

I was in a hurry; Jim was at the end station and sorely needed my assistance.  Anyway, despite several attempts, I was unable to transition either ITM to lower blends with the trilliums.  Oddly, the BS went fairly easily...