Start h1oaf model, restart DAQ

Kiwamu and Dave

WP4449:

modified h1boot to include first install of the h1oaf model.

13:11 started the first instance of the h1oaf model running on the front end h1oaf0.

changed the DAQ configuration to include the new model

13:26 DAQ restart

now changing the overview MEDM screens to include the h1oaf

Comments related to this report
david.barker@LIGO.ORG - 13:50, Wednesday 19 February 2014 (10183)

MEDM updates completed.

BTW: the new model added one Shared Memory IPC channel on the h1oaf0 frontend:

[H1:OAF-PEMCS_SHARED]
ipcType=SHMEM
ipcRate=16384
ipcHost=h1oaf0
ipcModel=h1oaf
ipcNum=0
desc=Automatically generated by IPCx.pm on 2014_Feb_19_10:44:10[H1:OAF-PEMCS_SHARED]
ipcType=SHMEM
ipcRate=16384
ipcHost=h1oaf0
ipcModel=h1oaf
ipcNum=0
desc=Automatically generated by IPCx.pm on 2014_Feb_19_10:44:10
kiwamu.izumi@LIGO.ORG - 14:03, Wednesday 19 February 2014 (10185)

In the latest oaf model, I intentionally deleted the IPC blocks for now which were supposed to receive signals from HEPIs and ISIs. In any case, the original motivation of starting the OAF model was to get the IMC signal received and saved as science frames, and this was achieved by this installation. At some point in the future, we should revisit the model and implement the IPC blocks back, which requires changes in some other models (see the detail in alog 9963).