Reports until 08:15, Thursday 20 February 2014
H1 SEI
hugh.radkins@LIGO.ORG - posted 08:15, Thursday 20 February 2014 - last comment - 17:01, Friday 21 February 2014(10201)
Thursday AM SEI States--All good except BS ISI Trip

The BS IS tripped on GS-13 watchdog at 1328 utc this morning.  Traffic, wind, something--plotting scripts still not functioning...

Anyway, I brought it back to lvl2 with 750mHz blends on stage2 and T250s on all Stage1 blends except T100mHz_0.44 blends on X & Y dofs.

I reset the target positions, there was about 700nrads on RX and <4um on Z, all other shifts were less.   Please let us know if this impacts any alignments.  This allowed for a one button isolation.

Comments related to this report
hugo.paris@LIGO.ORG - 09:57, Thursday 20 February 2014 (10207)

I reported the WD plotting issue mentioned by hugh last week. Details can be found in LHO aLog #10057

I am not sure what is going on yet, scripting or server access issue, but I am looking into it.

hugo.paris@LIGO.ORG - 10:12, Thursday 20 February 2014 (10208)

The plotting scripts work for the HAM-ISI. WD plotting is still disfunctional on the BSC. I think it is a scripting issue in that case, and I am working towards fixing it:

   Called with arguments: subsystem='ISI_ST1', debug=False, lookback=20, chamber='BS', lookforward=15, device='CPS', rough_trip_time=<object object at 0x7f70dd9050f0>, ifo='H1'
2014-02-20 10:09:21,199 : WDTripPlotter :
    Quitting program
Traceback (most recent call last):
  File "/opt/rtcds/userapps/release//isi/common/scripts/wd_plots/main.py", line 321, in <module>
    main()
  File "/opt/rtcds/userapps/release//isi/common/scripts/wd_plots/main.py", line 241, in main
    rough_trip_time, wd_trip_time_channel_name = util.get_rough_wd_trip_time(ifo, subsystem, chamber)
  File "/opt/rtcds/userapps/trunk/isi/common/scripts/wd_plots/util.py", line 33, in get_rough_wd_trip_time
    channel_suffix = const.WDMON_GPS_TIME_CHANNEL_SUFFIX[_subsystem]
KeyError: 'ISI'   Called with arguments: subsystem='ISI_ST1', debug=False, lookback=20, chamber='BS', lookforward=15, device='CPS', rough_trip_time=<object object at 0x7f70dd9050f0>, ifo='H1'
2014-02-20 10:09:21,199 : WDTripPlotter :
    Quitting program
Traceback (most recent call last):
  File "/opt/rtcds/userapps/release//isi/common/scripts/wd_plots/main.py", line 321, in <module>
    main()
  File "/opt/rtcds/userapps/release//isi/common/scripts/wd_plots/main.py", line 241, in main
    rough_trip_time, wd_trip_time_channel_name = util.get_rough_wd_trip_time(ifo, subsystem, chamber)
  File "/opt/rtcds/userapps/trunk/isi/common/scripts/wd_plots/util.py", line 33, in get_rough_wd_trip_time
    channel_suffix = const.WDMON_GPS_TIME_CHANNEL_SUFFIX[_subsystem]
KeyError: 'ISI'
hugo.paris@LIGO.ORG - 17:01, Friday 21 February 2014 (10259)

The BSC-ISI WD plotting software was fixed, see LHO aLog #10258 for more details.