Reports until 16:06, Thursday 20 February 2014
H1 SUS
duncan.macleod@LIGO.ORG - posted 16:06, Thursday 20 February 2014 (10222)
ODC summary bitmask for BS SUS changed to ignore M3 WatchDog
[Jeff K, Duncan M]

The H1:SUS-BS_ODC_CHANNEL_BITMASK record has been modified so that the summary bit of the ODC for BS suspension ignores the 'M3 WatchDog OK' bit, at Jeff's suggestion - this bit will be off for the foreseeable future, regardless of the state of the suspension itself.

This record now reads 2014, rather than 2046:

$ caput H1:SUS-BS_ODC_CHANNEL_BITMASK 2014
Old : H1:SUS-BS_ODC_CHANNEL_BITMASK  2046
New : H1:SUS-BS_ODC_CHANNEL_BITMASK  2014

An equivalent change has been made at LLO.