Reports until 13:45, Friday 21 February 2014
LHO VE
kyle.ryan@LIGO.ORG - posted 13:45, Friday 21 February 2014 (10248)
~1130 hrs. local -> Stopped pumping CP8 dewar's vacuum jacket
This completes dewar vacuum jacket pumping exercise.  Summary below: 

8514374 As found = 780 microns -> As left on 12/20/2013 TC = 4 microns, Pirani = 1.5 x 10-3 torr, 
8514372 As found = 28 microns -> As left on 1/23/2014 TC = 4 microns, Pirani = 1.4 x 10-3 torr, 
8514371 As found = 61 microns -> As left on 1/27/2014 TC = 7 microns, Pirani = 1.6 x 10-3 torr, 
8514375 As found = 45 microns -> As left on 1/31/2014 TC = 6 microns, Pirani = ? torr, 
8514376 As found = 49 microns -> As left on 2/4/2014 TC = 6 microns, Pirani = 1.7 x 10-3 torr, 
8514377 As found = 42 microns -> As left on 2/7/2014 TC = 6 microns, Pirani = 1.8 x 10-3 torr, 
8514379 As found = 81 microns -> As left on 2/13/2014 TC = 6 microns, Pirani = 2.0 x 10-3 torr, 
8514380 As found = 58 microns -> As left on 2/21/2014 TC = 7 microns, Pirani = 1.8 x 10-3 torr.