hugo.paris@LIGO.ORG - posted 16:52, Friday 21 February 2014 (10258)
BSC-ISI - WD Plotting Fixed

The BSC-ISI watchdog plotting software was reported disfunctional by Hugh earlier this week.

I looked into the scripts and they were fine. What I had missed is that Charles had updated the BSC-ISI WD screens, wich thus needed to receive an svn up at the site to match the latest wd_plotting software update, performed when updating the HAM-ISI models last week.

I run the the svn up on: /opt/rtcs/userapps/release/isi/common/medm/ISI_CUST_CHAMBER_WATCHDOg.adl remotely.

The WD plotting software now works on all the SEI platforms of H1.