Reports until 10:22, Monday 24 February 2014
H1 ISC
sheila.dwyer@LIGO.ORG - posted 10:22, Monday 24 February 2014 - last comment - 10:57, Monday 24 February 2014(10275)
27kHz noise was from polarization controller

The 27kHz line in the green locking was from the polarization controller, as Bram suggested.  Attached are plots of the PLL and PDH error signals with the MPC powered on and off.  

There is also a wandering feature in both signals that goes away when the MC is unlocked.  

Again this afternoon the single shot cavity alignment was good, but the dither alignment kept arriving at an alignment where the cavity axis was different from the single shot beam.  

Images attached to this report
Non-image files attached to this report
Comments related to this report
alexan.staley@LIGO.ORG - 10:57, Monday 24 February 2014 (10280)

There was an error in Sheila's matlab script in calibrating the PLL error signal. I have attached the new matlab file and plot. I have also attached the data concatenated.

Images attached to this comment
Non-image files attached to this comment