compiling all models against RCG2.8.3, refrain from model changes until tomorrow

In preparation for an RCG upgrade to version 2.8.3 tomorrow morning I am recompiling (but not installing) all models against 2.8.3. Please do no make any model changes or builds for the remainder of today.

In detail:

/opt/rtcds/rtscore/advLigoRTS-2.8.3 is a new checkout of the tags/advLigoRTS-2.8.3 released by Rolf today

/opt/rtcds/rtscore/release relinked to 2.8.3

New build area created

/opt/rtcds/lho/h1/rtbuild-2.8.3 and release pointer relinked to it

inside of rtbuild-2.8.3 the advLigoRTS-2.8.3/configure script was ran.

Comments related to this report
david.barker@LIGO.ORG - 17:26, Monday 24 February 2014 (10290)

Performed first round of builds on all models, four did not compile:

h1isiham3, h1iopseib1, h1susitmy, h1iscey

we are investigating why these are failing. 

H1.ipc file did not get modified after the first build of h1asc before the full build.

Displaying report 1-1 of 1.