Reports until 18:15, Monday 24 February 2014
H1 CDS
david.barker@LIGO.ORG - posted 18:15, Monday 24 February 2014 - last comment - 22:25, Monday 24 February 2014(10291)
status of model rebuild work

h1isiham3: Fabrice fixed h1isisham3, there was a new input port not grounded.

h1susitmy: is running a special trunk version with HWWD parts installed, will leave this model out of the upgrade

h1iscey: not spoken with the ISC group on this one yet

h1iopseib1: a real puzzler. the model has not been changed since 14 Nov, it compiled 16 Dec but wont compile on either 2.8.3 or 2.8.2 today. the H1.ipc file was changed, but this model receives the same IPC channel as h1iopseib2,3 and they compile fine. Comparing the models by eye shows no difference. I copied the Rx part from seib2 to seib1 and still b1 fails and b2 compiles. Will need to scratch our heads a little more. Perhaps a regeneration of H1.ipc from scratch is in order.

Comments related to this report
daniel.sigg@LIGO.ORG - 22:25, Monday 24 February 2014 (10297)

h1iscey probably needs to be updated to the EX version. We made some changes in the common blocks to include the ALS WFS which have not been propagated to EY. Not sure why we need to keep separate configuration files for EX and EY.