H1 upgraded to RCG2.8.3

Jim and Dave

We compiled all the front end models against 2.8.3 except for the three models mentioned previously.

I installed all the models using the install-World option and a modified local rtsystab to skip aforementioned models.

I then did a DAQ restart to see if any INI files were modified which we were not expecting, and we were surprised by h1odcmaster and h1susetmy which have modified INI files. h1lsc was modified by this was expected due to Jamie's new model.

We then logged into each front end and restarted the models. Since IOP models were being restarted the sequence was

stop all user models

restart the iop model

start all the user models

As usual we had to press the BURT button on many models before they timed out.

GOTCHA. the bug which doesn't allow the h1odcmaster to be restarted without crashing the h1oaf0 computer was tested and is still there! Jim was able to take this node out of the dolphin fabric so we didnt have to re-restart anything.

PSL was the first to be restarted. I burt restored to 09:00 today and opened the shutter from the MEDM screen. All looks good.

I then viewed the safe.log files for each model to see which ones reported many connection errors. For those with more then a few dozen I manually burtrestored the following to 09:00 this morning;

hpiham[4,5,6]  isiham[2,3,5,6] sustmsy, suspr3, susim, susitmy, lsc

I tried burt restoring h1susetmy but it had errors due to a model change.