Ops summary 20140226

9:00 Kris to EX, back at noon

9:30 HughR, MitchR to HAM4, done at 10:30

10:00 Kiwamu PR2 Model changes, multiple DAQ restarts

10:00 ETMX ISI & ITMX ISI and HPI found to be down. ETMX came back up, ITMX HPI would not. ITMX HPI has been down since yesterday's boot fest. Looks like the HPI IPS targets got lost during a burt restore. This was not recovered until the afternoon. It required finding an older burt file, then redoing the safe.snap.

10:15 CoreyG to EX TMS lab. Travis to LVEA SUS test stand.

10:30 HughR, MitchR to EY for cabling. Done at 12

11:00 I went to HAM4 for a fruitless troubleshooting mission. Problems fix themselves.

11:15 DaveB restarting BS-ISI.

12:30 Cleaning crew to EY. Done 15:00

13:00 Ed and Evan to IOT2R. Transitioning to laser hazard.

14:00 CraigC, RIckS, ChrisS  to H2 PSL.

14:00 JeffB, AndresR to HAMs 2,4&5 hunting for install hardware. Done 15:00