Displaying report 1-1 of 1.
Reports until 15:50, Wednesday 26 February 2014
H1 SEI
sheila.dwyer@LIGO.ORG - posted 15:50, Wednesday 26 February 2014 (10359)
ETMX sensor correction helps

Fabrice's sensor correction for ETMX stage 2 was just turned back on (in the last few minutes).  I did this by turning on the output of H1:ISI-ETMX_ST2_SENSCOR_X_MATCH and setting the gain H1:ISI-ETMX_ST2_SENSCOR_X_MATCH_GAIN=1.15.  This helped the pitch motion. 

In the attached screenshot you can see that it clearly helped to reduce the pitch motion.

Images attached to this report
Displaying report 1-1 of 1.