Reports until 18:05, Wednesday 26 February 2014
H1 ISC
stefan.ballmer@LIGO.ORG - posted 18:05, Wednesday 26 February 2014 (10363)
Hitting Baffle PDs
Below are a series of reference alignment values that allow hitting the various BAFFLE PDs:

# TMS pointing straight shot
# ITMX PD1
caput H1:SUS-ETMX_M0_OPTICALIGN_P_OFFSET 0
caput H1:SUS-ETMX_M0_OPTICALIGN_Y_OFFSET 0
caput H1:SUS-TMSX_M1_OPTICALIGN_P_OFFSET 203.3
caput H1:SUS-TMSX_M1_OPTICALIGN_Y_OFFSET -228.1



# TMS pointing straight shot
# ITMX PD3 (PD4)
caput H1:SUS-ETMX_M0_OPTICALIGN_P_OFFSET 0
caput H1:SUS-ETMX_M0_OPTICALIGN_Y_OFFSET 0
caput H1:SUS-TMSX_M1_OPTICALIGN_P_OFFSET 272.7
caput H1:SUS-TMSX_M1_OPTICALIGN_Y_OFFSET -289.7



# ITM pointing
# ETMX PD1
caput H1:SUS-ETMX_M0_OPTICALIGN_P_OFFSET 0
caput H1:SUS-ETMX_M0_OPTICALIGN_Y_OFFSET 0
caput H1:SUS-ITMX_M0_OPTICALIGN_P_OFFSET 35.3
caput H1:SUS-ITMX_M0_OPTICALIGN_Y_OFFSET -69.2
caput H1:SUS-TMSX_M1_OPTICALIGN_P_OFFSET 238.0
caput H1:SUS-TMSX_M1_OPTICALIGN_Y_OFFSET -258.9


# ITM pointing
# ETMX PD4
caput H1:SUS-ETMX_M0_OPTICALIGN_P_OFFSET 0
caput H1:SUS-ETMX_M0_OPTICALIGN_Y_OFFSET 0
caput H1:SUS-ITMX_M0_OPTICALIGN_P_OFFSET 67.4
caput H1:SUS-ITMX_M0_OPTICALIGN_Y_OFFSET -36.3
caput H1:SUS-TMSX_M1_OPTICALIGN_P_OFFSET 238.0
caput H1:SUS-TMSX_M1_OPTICALIGN_Y_OFFSET -258.9


# ETM pointing
# ITMX PD1
caput H1:SUS-ETMX_M0_OPTICALIGN_P_OFFSET 231.4
caput H1:SUS-ETMX_M0_OPTICALIGN_Y_OFFSET 90.8
caput H1:SUS-ITMX_M0_OPTICALIGN_P_OFFSET 51.35
caput H1:SUS-ITMX_M0_OPTICALIGN_Y_OFFSET -52.75
caput H1:SUS-TMSX_M1_OPTICALIGN_P_OFFSET 238.0
caput H1:SUS-TMSX_M1_OPTICALIGN_Y_OFFSET -258.9


# ETM pointing
# ITMX PD3 (PD4)
caput H1:SUS-ETMX_M0_OPTICALIGN_P_OFFSET 255.4
caput H1:SUS-ETMX_M0_OPTICALIGN_Y_OFFSET 60.7
caput H1:SUS-ITMX_M0_OPTICALIGN_P_OFFSET 51.35
caput H1:SUS-ITMX_M0_OPTICALIGN_Y_OFFSET -52.75
caput H1:SUS-TMSX_M1_OPTICALIGN_P_OFFSET 238.0
caput H1:SUS-TMSX_M1_OPTICALIGN_Y_OFFSET -258.9