all models on h1seih23 restarted to clear frozen DAC outputs

Fabrice, Jamie, Jim, Dave

I restarted all the models on h1seih23 to clear the no-DAC-output problem.

Sequence was: stop user models, restart IOP model, start user models

models are h1isiham2,3 h1hpiham2,3 h1iopseih23

Fabrice then put ISI ham 2,3,4,5,6 into a safe state, and I updated the safe.snap files in SVN and committed them.

Comments related to this report
keith.thorne@LIGO.ORG - 18:50, Thursday 27 February 2014 (10395)
Has the /etc/startWorld.sh script been installed on H1 front-ends?  That is what is used at L1 for these restarts.