Reports until 13:07, Thursday 27 February 2014
H1 ISC
jaclyn.sanders@LIGO.ORG - posted 13:07, Thursday 27 February 2014 - last comment - 10:19, Friday 28 February 2014(10382)
COMM PLL repairs

(Alexa, Jax, Stefan)

Alexa was trying to hunt down a missing gain factor for her model and instead found a busted COMM PLL board (serial number S1200564). The op-amp for the VCO compensation stage (U37) was blown. I recalled replacing the same op-amp on the DIFF PLL about a month ago, suggesting that there's something that makes this particular op-amp vulnerable. After discussing with Richard McCarthy, we opted to change resistor R96 from 0 to 2k ohms to protect the poor thing. Lab tests show that it's in good shape, and it'll be back to the ISC rack as soon as we're done with the ISC meeting.

Comments related to this report
peter.fritschel@LIGO.ORG - 13:51, Thursday 27 February 2014 (10384)

Should this resistor change be propagated to all PLL boards?

jaclyn.sanders@LIGO.ORG - 13:56, Thursday 27 February 2014 (10385)

No, we're still thinking about it. It's going in as modified and if it keeps having problems, we'll burn that bridge when we get to it.

jeffrey.kissel@LIGO.ORG - 10:19, Friday 28 February 2014 (10406)
This smells of an ISC integration issue so we don't forget...