I telneted into the procServ IOC for end Y and saw the following error messages: epics> attempting to connect to host: 10.1.3.64 port: 8003 Error: tcp_connect: socket: Too many open files CAS: Client accept error was "Too many open files" attempting to connect to host: 10.1.3.64 port: 8003 Error: tcp_connect: socket: Too many open files attempting to connect to host: 10.1.3.64 port: 8003 Error: tcp_connect: socket: Too many open files attempting to connect to host: 10.1.3.64 port: 8003 Error: tcp_connect: socket: Too many open files CAS: Client accept error was "Too many open files" I restarted the IOC, and the errors did not reappear, but none of the expected state reporting messages were shown. I tried pinging the Comtrol at 10.1.3.64 and did not get a response.
The switchport for the Comtrol has been down since Friday afternoon. The Comtrol box is probably unplugged/powered off.