This morning I went to the EY and floated the ISI. Fairly straight forward, with no difficulties to report. I also adjusted lockers, fixed some cabling issues and re-gapped the CPS's. I then went into the chamber below (mostly to retrieve some hardware I dropped (sorry Betsy)) and plugged in a cable for Richard. I left the ISI locked, in case any other teams need to go in and work. As far as SEI is concerned, we are ready for TF's.