Reports until 16:20, Tuesday 04 March 2014
H1 AOS (AOS)
douglas.cook@LIGO.ORG - posted 16:20, Tuesday 04 March 2014 (10504)
ETMy/BSC10 IAS alignment
Results of todays look at the suspended optic:

Longitudinal using the same corner cube to optic offset as measured on the test stand (454.3mm) added to the EDM shot = 5629.3mm, desired distance 5629.8, error o.50mm. Tolereance of +/- 3mm

Latitude desired tolerance (beamline) +/- 1.0mm, measurement 1.4051mm Error correction .4051mm minimum. Needs to move south direction.

Vertical desired tolerance beamline +/- 1.0 mm, measurement -1.1054mm. Error .1054 mm minimum. Needs to move up.

Pitch: desired 639 urad up +/- 100urads. Error 275urads  (angle set at 89deg, 57', 48" = 0urads) optic needs to pitch down.I used an iris to prevent AR side clipping

Yaw: desired 270deg +/- 100urads. Error 1.0 mrads urads. ISI/SUS needs to rotate ccw

Looks like some HEPI tweaks are next and another round of measurements