We had a lot of trouble early in the evening isolating ETMX, we kept tripping the watchdog on stage 2. We tried reseting the CPS offsets, and eventually were able to get it to isolate with Tcrappy and level 2 controllers, but the motion was rather large (~ten fringes per second). We left stage 2 with damping only.
We haven't been using feedback to HEPI, and turned off the feedback to the top mass when we started having trouble. there were acutator trips, GS13 trips, and T240 trips (I frogot to disable the T240 watchdog once).