IAS: D. Cook, J. Oberling
SEI: J. Warner, G. Grabeel, M. Robinson
Aligned the X, Y, and Z positions and Yaw of the ETMy this morning. The errors are as follows:
-
Longitudinal: +0.5 mm
-
Lateral: +0.2 mm
-
Vertical: -0.1 mm
-
Yaw: 20 µrad CW
-
Target: 0 µrad
-
Tolerance: ±50 µrad
All is within spec, we are ready to move forward with HEPI actuator attachment; IAS will take another look afterwards to ensure we are still within spec.