Last Night's ETMY Trip
J. Kissel, J. Warner

Jim had reported in the morning install meeting that H1 SUS ETMY had tripped at ~12:30a PT last night after a few bands of transfer functions. Turns out the reaction chain (R0) had tripped alone, because its damping loops were OFF. I've ensured the loops are installed, and turned them ON.