Displaying report 1-1 of 1.
Reports until 11:14, Thursday 06 March 2014
H1 SEI
jeffrey.kissel@LIGO.ORG - posted 11:14, Thursday 06 March 2014 (10584)
Corner Station BSC-ISIs All Trip at 10:32a PT
J. Kissel, J. Bartlett

Unclear if there was any smoking gun, but H1 ISI BS, H1 ISI ITMX, and H1 ISI ITMY all tripped at 10:32a PT (1078165983). PRCL team was in LVEA near IOT2, Andres was working near Test Stand, nobody doing any heavy lifting, no earthquakes.

ISI Configs:
Chamber      Isolation Filters      Blend Filters       First Trigger
ITMX         Level 3                   TCrappy             ST1 T240
ITMY         Level 3                   TCrappy             ST1 Act
BS           Level 3                T40mHz_N0.44           ST1 Act

Images attached to this report
Displaying report 1-1 of 1.