Per Keita's ALOG 10331 and 10454, I have adjusted the optical lever calibration gains for ETMX and ITMX to reflect a more accurate method of calibration that was performed by Keita with the baffle diodes.
ETM
| Old | Delta | New | |
| Pitch | 76.7 | 0.932 | 71.4844 |
| Yaw | 65.3 | 0.863 | 56.3539 |
ITM
| Old | Delta | New | |
| Pitch | 23.4 | 2.081 | 48.6954 |
| Yaw | 24.7 | 2.287 | 56.4889 |