Model and DAQ restarts

WP4488, new h1asc and h1lsc models, new DAQ channels

I SVN updated the LSC and ISC common/models area, carefully checking only the updates I expected were received. Rebuilt and installed the h1asc and h1lsc models

10:46 PST h1asc restarted

11:12 PST h1lsc restarted

11:40 DAQ restarted

The DAQ restart had problems restarting the DMT broadcaster. I had to kill and restart monit which in turn restarted daqd, which got running at 11:49PST.

Other changes ingested by this DAQ restart:

Note, h1pemmy was not added during this reconfiguration, that will require a separated DAQ restart.

ASC and LSC DAQ changes summarized below

model num fast chans [before,after] num slow chans [before,after] DAQ data rate kB/s [before, after]
h1asc 76,78 17444,17650 1739,1768
h1lsc 120,124 3048,3048 2733,2995