Displaying report 1-1 of 1.
Reports until 13:44, Friday 14 March 2014
H1 ISC
sheila.dwyer@LIGO.ORG - posted 13:44, Friday 14 March 2014 - last comment - 13:50, Friday 14 March 2014(10760)
Help from DetChar or SEI offsite?

We've had at least 6 times this morning that HEPIs have tripped on the L4Cs, and there isn't a clear reason looking at the seismic conditions why today should be worse than other days.  The chambers that have tripped are (at least ) IMTX twice, ITMY once, HAM2 once, BS twice.  Attached are plots of the two most recent BS trips. 

No one on site really has the time to sort through the data and figure out what is happening, is there anyone from SEI or DetChar that can take a look?

Thank you,

Sheila

Images attached to this report
Comments related to this report
fabrice.matichard@LIGO.ORG - 13:50, Friday 14 March 2014 (10761)

Sheila,

thanks for the note. We start looking into it.  Since the L4C are not even in the loop, please feel free to temporarily rise the WD value (the code will slowly bring it back to standard value at teh rate of 1 ct/s or so).

We get back to you asap. 

Displaying report 1-1 of 1.