Displaying report 1-1 of 1.
Reports until 16:24, Tuesday 25 March 2014
H1 AOS (AOS)
david.ottaway@LIGO.ORG - posted 16:24, Tuesday 25 March 2014 - last comment - 15:18, Thursday 27 March 2014(10996)
H1 Output Faraday Isolator Performance
Dave O, Gerado,

The performance of the Output Faraday Isolator was tweaked and a transmission of 96.5 +/- 0.5% was recorded and an isolation of 9e-5 was measured. See attached report for more details.
Non-image files attached to this report
Comments related to this report
david.ottaway@LIGO.ORG - 15:18, Thursday 27 March 2014 (11038)
We also used the Shack Hartmann Sensor to put and limit on the spherical power introduced by the Output Faraday Isolator (See attached document) 
Non-image files attached to this comment
Displaying report 1-1 of 1.