Reports until 15:09, Thursday 27 March 2014
H1 SUS (DetChar, SEI)
jeffrey.kissel@LIGO.ORG - posted 15:09, Thursday 27 March 2014 - last comment - 15:42, Thursday 27 March 2014(11036)
Fixed ITMX and ETMX CART2EUL Matrices
J. Kissel

While using the channels that project the ISI ST2 GS13s in the Cartesian basis to the Test Mass QUAD suspension point in the Euler basis for the X-arm QUADs, i.e. H1:SUS-?TMX_M0_ISIWIT_?_DQ, I noticed that the projection matrices that create these channels were a copy-and-paste from the Y-arm, and therefore wrong by 90 [deg]. I've corrected the matrices at around 2014-03-27 21:55 UTC, saved, and committed a new safe.snap such that they stick.

Details for the record:
-----------------------
These matrices are calculated using the script
/ligo/svncommon/SusSVN/sus/trunk/Common/MatlabTools/make_ISI2SUS_projections.m
which takes in the locations of each SUS from the parameter file
/ligo/svncommon/SusSVN/sus/trunk/Common/MatlabTools/SEI2SUScoordinates.m
based on the systems SolidWorks drawings for that suspension. 

They are pre-calculated and stored in the mat file
/opt/rtcds/userapps/release/isc/common/projections/ISI2SUS_projection_file.mat
which I loaded into a matlab and ran the function 
/ligo/svncommon/SusSVN/sus/trunk/Common/MatlabTools/fill_matrix_values.m
to automatically fill in the epics values.

The theory behind these projections can be found in T1100617

#yakshaving
Comments related to this report
jeffrey.kissel@LIGO.ORG - 15:12, Thursday 27 March 2014 (11037)DetChar, ISC, SEI
I checked and confirmed that the TMSX CART2EUL matrix is also wrong, but I didn't fix it because the parameter file doesn't have the coordinates for the TMS pulled from the systems drawings yet, and I'm already distracted enough. We'll get to it later.
jeffrey.kissel@LIGO.ORG - 15:42, Thursday 27 March 2014 (11040)
And now the plots makes sense, and we can do science again.

Look at the tilt (ISI RY) contribution to Longitudinal Motion at the suspension point! This is now, at no particular time. Now on to look a Sheila's data from yesterday (see LHO aLOG 11026).
Non-image files attached to this comment