patrick.thomas@LIGO.ORG - posted 16:07, Thursday 27 March 2014 (11041)
H1 PSL check
Laser is on
Output power is 28.1 W (should be 30 W)
Watchdog is active
No warnings in PSL SYSSTAT.adl other than "VB program online" 

PMC
Locked for 4 days 3 hours (should be days/weeks)
Reflected power is 12.7% of transmitted power (should be 10% or less)

FSS
Reference cavity is not locked
Trans PD threshold is .4 V (should be at least .9 V)

ISS
Diffracted power is around 7.8% (should be around 10%)
Last saturation event was 11 minutes ago (should be days/weeks)