WFS Comissioning

(Alexa, Daniel, Sheila)

We measured the WFS sensing matrix for both PIT and YAW. The matrices were computed by exciting ITMX/ETMX PIT/YAW at 1.5Hz with 0.3 amplitude, and looking at the WFS transfer function. The results can be found in the following DTTs saved in /ligo/home/sheila.dwyer/ALS/HIFOX/WFS/:

Inverting the results gives...

YAW input sensing matrix:

-2.294    -3.155

0.529     -2.604

PIT input sensing matrix:

-0.494    -0.239

0.302    -0.489

These values are in microradians; however the factor of 1e-3 is taken care of in the gain of the filter module. We also adjusted the signs as follows:

Under this configuration, with all four DOFs engaged (DOF 1,2 P,Y) the WFS_A/B_I_YAW/PIT_OUTMON all converge to zero. The lock appears to be stable with a transmission betweeen 950 to 1050 counts. Futher investigation needs to be done...