arnaud.pele@LIGO.ORG - posted 18:39, Friday 28 March 2014 - last comment - 18:41, Friday 28 March 2014(11067)
ETMX UIM filter tested

This week, I tested the ETMX UIM P2P and Y2Y filters (described in alog 10912). The results are showing that filters are working as expected giving a single pendulum transfer function falling at 1/f^2 after the resonnance (f=0.45Hz for pitch, f=0.6Hz for yaw). Also the coupling between pitch and yaw is small (~5%) so unless this is too much, there's no need for diagonalization for UIM.

Attached pdf are showing P2P P2Y (first pdf) Y2Y Y2P (second pdf) transfer functions with/without the filter.

Left to do for next week :

ETMX : Long decoupling on UIM/PUM

ETMY

ITMX/ITMY

Non-image files attached to this report
Comments related to this report
arnaud.pele@LIGO.ORG - 18:41, Friday 28 March 2014 (11080)

sorry for the 90degrees rotated pdfs ! couldn't find a way to rotate and save them.