daniel.sigg@LIGO.ORG - posted 09:26, Monday 31 March 2014 - last comment - 10:33, Monday 31 March 2014(11090)
Commissioning calendar for next 2 weeks

Here is the list of commissioning task for the next 7-14 days:

Green team:

Red team:

Blue team (ALS WFS):

Blue team (ISCTEY):

SEI/SUS team:

Comments related to this report
jeffrey.kissel@LIGO.ORG - 10:33, Monday 31 March 2014 (11091)SUS
Daniel means increasing the UIM driver range, as per ECR E1400164 and integration issue 762. Note, also, that after conversations with LHO staff and subsequent follow up with P. Fristchel, it has been agreed that we should modify all four UIM drivers (not just the ETM drivers as mentioned in the current versions of the ECR and II).

Also by ETMY Diagonalization, he means (once the optical lever installation is complete)
- Balancing the coils on the UIM and PUM stages
- Gathering measurements, designing, and installing filters for 
    - Length-to-Angle frequency dependent decoupling
    - P and Y plant compensation filters for WFS.
 (See LHO aLOG 11067 for list of measurements.)