aidan.brooks@LIGO.ORG - posted 17:32, Monday 31 March 2014 (11103)
TCS CO2X laser install: laser running. Replacing laser. Laser Enable Procedure

Aidan. Thomas. Greg. Eric G. Dave H.

Today's work

Flow meter issue

Wired up flow meter. The wiring was 

CO2 Controller Chassis

Leaky laser was enabled

Laser (SN 20510.20816D) was run. Maximum output power was 49.4W

Beckhoff issues

CO2 binary outputs not working - traced problem to Beckhoff System Manager not mapping CO2 output hardware to PLC variables.

Plumbing

 

Laser Enable Procedure

It actually takes a large number of ducks to be in a row to turn these CO2 lasers on. So here's how to do it ...

 

  1. Ensure that the laser power cables are connected from the Instek Power Supply (Mech Room) to the CO2X table feedthroughs and, inside the table, connected to the RF driver

  2. Mech Room: Turn on the chiller. Check flow rate is approximately 3.5GPM and pressure is abotu 60psi on the chiller. Check that H1:TCS-C_CO2_X_FLOWRATE is about 3.5GPM
  3. Mech Room: Turn on Instek power supply. Set output voltage to 29.5V. Set the maximum current to ~28A. Press the enable output button. Check that the current drawn is around 350mA.
  4. Mech Room: Turn on the oscillator to 40.68MHz, 11dBm. Ensure the output is connected all the way to the laser table, through the feedthrough and into the Sine-To-TTL box
  5. Laser Controller: Ensure all inputs are plugged in.
  6. Beckhoff: Set H1:TCS-C_CO2_X_LASERPOWERSWITCH to Valid
  7. Laser Table: Ensure the ISS Chassis is turned on
  8. Laser Table: Ensure the BO chassis is turned on
  9. Laser Controller: Select pulse width modulation (PWM) or continuous wave (CW)
  10. If PWM: connect the external controller
  11. Laser Controller: (Turn Key off). Turn Key on.
  12. Laser Controller: Press the Red Gate ON/OFF button
  13. If PWM: turn the dial on the external controller to the desired PWM %.
  14. If PWM: press the enable button on the external controller.

The success of this can be gauged by checking:

  1. The Instek controller current (H1:TCS-ITMX_CO2_PWR_SUPPLY_I_OUTPUT): should be about 20A at full CW. Or > 1A when laser is running at any power level.  
  2. The pick-off on the laser head (H1:TCS-ITMX_CO2_LSRPWR_HD_PD_OUTPUT) should rise to about 45-50W (if calibrated correctly).
  3. The temperature of the laser (H1:TCS-C_CO2_X_LASERTEMPERATURE) should increase to about 23-24C
Displaying report 1-1 of 1.