Reports until 14:42, Wednesday 02 April 2014
H1 SEI
arnaud.pele@LIGO.ORG - posted 14:42, Wednesday 02 April 2014 (11134)
ETMY GS13 V2

[Rich M. Arnaud]

ETMY GS13 V2 input signal was sitting at around 6000cts whereas the others at ~100 cts. Turning off/on the digital Gain + DWH switches brought it back to ~1000cts. Better. Though, it seems like there is still an offset that adds up to the signal.