will run for ~ 16 hours (undamped / damped for main and reaction chain)
FInished when checked 4/7 (Arnaud is away).
M0 undamped: 2014-04-02-1080519986_H1SUSETMY_M0_0p01to50Hz_tf.mat
M0 damped: 2014-04-02-1080537980_H1SUSETMY_M0_0p01to50Hz_tf.mat
R0 undamped: 2014-04-03-1080555846_H1SUSETMY_R0_0p01to50Hz_tf.mat
R0 damped: 2014-04-03-1080573824_H1SUSETMY_R0_0p01to50Hz_tf.mat
Everything looks good except that as usual the R0 cabling has pushed the pitch modes up in frequency.
Comparison plots pending.
FInished when checked 4/7 (Arnaud is away).
M0 undamped: 2014-04-02-1080519986_H1SUSETMY_M0_0p01to50Hz_tf.mat
M0 damped: 2014-04-02-1080537980_H1SUSETMY_M0_0p01to50Hz_tf.mat
R0 undamped: 2014-04-03-1080555846_H1SUSETMY_R0_0p01to50Hz_tf.mat
R0 damped: 2014-04-03-1080573824_H1SUSETMY_R0_0p01to50Hz_tf.mat
Everything looks good except that as usual the R0 cabling has pushed the pitch modes up in frequency.
Comparison plots pending.