Reports until 07:22, Tuesday 08 April 2014
H1 PSL (DetChar, IOO)
laura.nuttall@LIGO.ORG - posted 07:22, Tuesday 08 April 2014 - last comment - 08:33, Friday 11 April 2014(11212)
PSL and IMC ODC look odd
Since Saturday the ODC for the PSL and (obviously) IMC have looked a little odd. They both keeping reporting very short, quick times when both the systems are not 'good'. These happen throughout the day as you can see by the two attached plots which show yesterday's activities (you can see more of these plots on the summary pages - https://ldas-jobs.ligo-wa.caltech.edu/~detchar/summary/). Just wanted to check you knew about this and if so is this nothing to worry about? Thanks! 
Images attached to this report
Comments related to this report
stefan.ballmer@LIGO.ORG - 08:33, Friday 11 April 2014 (11284)
This was another iteration of the ISS actuation running into its range limit.