Displaying report 1-1 of 1.
Reports until 10:49, Friday 29 July 2011
H2 SEI
vincent.lhuillier@LIGO.ORG - posted 10:49, Friday 29 July 2011 (1123)
Damping loops - ISI - BSC8 - LVEA
The damping loops have been closed on the ISI-BSC8 using the experimental model. Before setting up the damping filters, actuators and geophones symmetrization filters were also installed. No time was spent on tuning. All damping loops have the same poles and zeros. Powerspectra when the ISI is non-controlled and controlled can be found at:

https://svn.ligo.caltech.edu/svn/seismic/BSC-ISI/H2/ITMY/Data/Figures/Powerspectra/Damping/
Matlab:
LHO_ISI_BSC8_Powerspectra_CT_ST1_L4C_Undamped_Damped_2011_07_29.fig
LHO_ISI_BSC8_Powerspectra_CT_ST2_GS13_Undamped_Damped_2011_07_29.fig

PDF:
LHO_ISI_BSC8_Powerspectra_CT_ST1_L4C_Undamped_Damped_2011_07_29.pdf
LHO_ISI_BSC8_Powerspectra_CT_ST2_GS13_Undamped_Damped_2011_07_29.pdf
Displaying report 1-1 of 1.