Reports until 16:00, Monday 14 April 2014	
	
		
		
		
		
			corey.gray@LIGO.ORG - 
posted 16:00, Monday 14 April 2014 (11315)
			
			
		
		
			
	Day's Activities:
	- 
		8:50 Gerardo closing GV5& GV7--finished before 10am
- 
		9:15 Jodi doing ACB inventory west bay
- 
		9:25-10:30 Vertical leveling HAM5 ISI (hugh, greg)
- 
		9:35 Jeff B will be looking at dust monitors around HAM5
- 
		9:35 ISC cabling investigations at EY by Filiberto/Aaron
- 
		9:50 Switching Blend Filters on BSC9 ISI (Arnaud)
- 
		10:10 Apollo finished moving Cleanroom off X-arm spool
- 
		10:17 David working around TCSx Table
- 
		10:24 Kyle valving out of EY Vacuum Equipment to make it quieter for Arnaud (may see pressure rise to this valve stuff)
- 
		10:30 Opening GV7 for Commissioning (Gerardo)
- 
		10:40 Beer Garden stairs craned out by Apollo
- 
		12:50 Jim MY weather station is now online
- 
		Kyle fixed MX Instrument air:  broken belt compressor
- 
		Jim worked on BSC10 ISI with measurements most of the day
- 
		Arnaud worked on ITMy
	Alarms in the morning: 
	- 
		CDS:  Lots of State Words RED & both ETMs had CPU Max
- 
		VAC:  MX instrument Air alarming constantly (since Fri morning)
- 
		SUS WD:  ITMy DAQ kill
- 
		DUST:  Lots of INVALID (as normal?), & LAB was alarming