To be absolutely clear, my understanding is that the new threshold is NOT actually 60s worth of saturations, but
60 * (model sample rate in Hz) samples worth of single-sample saturations that will now cause trips.
This is a big and important distinction. The first will trip after 60s worth of continuous saturations; the second will trip in an indeterminate time after the first saturation after a reset.
Please correct me if this is not right but this is my understanding of the new behavior, and it's important that everyone is clear on it.
60 x (model rate) = (number of saturated samples allowed) is what I coded into the master model, and what I meant by "60s worth of saturations" without realizing it could be misunderstood.
HEPI-L4C saturation counter will keep accumulating regardless of whether the saturations are continuous or not, until the reset button is pushed, or HEPI trips.