ITMX trips

The first one I was switching blends, plot attached.  The next two we don't know why they happened, we only got one plot.

Images attached to this report
Comments related to this report
sheila.dwyer@LIGO.ORG - 14:11, Tuesday 15 April 2014 (11357)

I tried moving to Tcrappy and it tripped again as I tried to turn it on

Images attached to this comment
stefan.ballmer@LIGO.ORG - 14:34, Tuesday 15 April 2014 (11360)
Hugo found that the problem was that some gain switches were set incorrectly.  This is something that it would be nice to have the Guardian control. 

PS, this is sheila
hugo.paris@LIGO.ORG - 14:35, Tuesday 15 April 2014 (11361)

Input gains were turned off on half the T240. We turned them back on, and ITMX is now running on TCrappy.