Displaying report 1-1 of 1.
Reports until 11:34, Thursday 17 April 2014
H1 SEI (CDS)
sheila.dwyer@LIGO.ORG - posted 11:34, Thursday 17 April 2014 (11407)
ISI trips, bringing guadirans back after model restarts

We had a whoe lot of trips this morning, first Hugho's model restart brought things down, then we had several trips related to people working on the cleanrooms in the beergarden.  One of those is plotted below.

After the model restarts, all the guardians are in the error state.  This means that someone has to go through and set them to load, then back to exec one at a time, which is somewhat time consuming.  This also happens after a beckhoff restart.  Jeff B is going through and doing this for us now, but it is somewhat time consuming when there are three guardians for each BSC ISI model, and will probably only become more so as time goes on. 

Is there a way to make this easier/quicker?

Also, everyone who restarts frontends from now on should probably add checking that the relevant guardians are running as the last step of the process.